Supermicro disable ipmi failover

Last UpdatedMarch 5, 2024

by

Anthony Gallo Image

Supermicro disable ipmi failover. ipmitool lan set 1 ipsrc dhcp. RE: How to disable IPMI. AST2600’s design is specifically based on Dual-core ARM Cortex A7 and various hardware interfaces including as Root of Trust (RoT), MCTP over PCIe, and dual JTAG master, supporting modern remote manageability on Supermicro platforms. 3. 此命令列介面工具可在 UEFI、DOS、Windows 與 Linux 作業系統上執行,毋需安裝。. – That is CVE-2013-4782, CVE-2013-4783, CVE-2013-4784, CVE-2014-2955. IPMI KVM (X9DRD-if motherboard, SuperMicro server) WORKED WITH. Share the IPMI VLAN with something else that the ESXi host is using, such as management, if you’re using a switch that can only provide For question 3, the answers are in both manuals. Rev. But apparently Mouse + keyboard input works during blackscreen. If no IP address shows up then of course you won't be getting into the IPMI. Sensors can be viewed in basic or advanced mode. Remote NM (Node Manager) 2. IPMICFG-Windows. IE 10 by default still uses TLS 1. The fix is to change the setting from "Failover" to "Dedicated". 其命令列工具提供了標準 IPMI 指令與 Supermicro 專屬的 OEM 指令用於作 BMC/FRU 配置。. Core. Single Socket Socket H4 (LGA-1151) supported, CPU TDP supports Up to 95W TDP. I mistakenly updated the firmware first through IPMI, then tried to update bios. Select “Controller Properties”. ipmicfg -sdr to find chassis intrusion sensor number. Here you can see the IP address as well as configure the settings such as a static IP address and gateway. Subsequently, after completion of the POST, the main screen of the BIOS will be displayed. These vulnerabilities include plaintext authentication, weak encryption, and authentication bypass within the Virtual Media capabilities. If its untagged on the switch you won't need to specify the vlan id in your ipmi config. X10SLM+/X10SLL+ Motherboard Series User's Manual Connecting Cables This section provides brief descriptions and pin-out definitions for onboard headers and connectors. 3 (2015) Supermicro 721TQ-350B NAS case (replaced Norco ITX-S4 2021) Currently the port on the L2 switch is empty for VLAN1 and Untagged for VLAN10. Log into the IPMI web interface by entering the IP address into the URL of a web browser on a client system. Boot. You can use IPMICFG utility to disable the sensor. exe -m 192. Download the latest IPMICFG utility released by Supermicro. In order to disable the IPMI, please login the IPMI site and select Configuration -> LAN Select -> Enable -> Dedicated LAN (only) then click SET to save it. Title: Microsoft Word - Disable BMC Virtual Media Author: IgorD Created Date: 9/4/2019 11:26:45 AM In an effort to expand IPMI capabilities, many companies and organizations have built more extensive management control into IPMI using OEM extensions. Sep 3, 2013 · Reply Reply Privately. Download IPMI Config to a text file. Dec 22, 2016 · Contacting Supermicro Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. exe –conf tdownload <file>. Now, you can connect a browser to the IP (e. This will block all access to the IPMI, since Rule 1 takes precedence over Rule 2 and will block all IP, even though you have Rule 2 set to allow your IP. 3. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro. 0 or greater. I believe the alarm is occurring because of the chassis intrusion detection since I have the chassis open currently. The management interface prompts for login credentials. Initially, we log into the panel and click the Maintenance tab. この CLI ベースのユーティリティは、UEFI、DOS、Windows、Linux の OS 上で実行する Oct 19, 2018 · The basic BMC and IPMI default logins are well-known. Mar 25, 2018. Mar 20, 2017 · I thought I was being prudent leaving IPMI disconnected but instead I was inadvertently exposing my whole network to a massive security hole. If you go into the IPMI web interface you can change the failover mode. but i unplugged the IPMI cable, it is not failover to LAN1 on X9SCM-F, while LAN1 is also used by esxi. For security purposes, TLS 1. Enter your email address below if you'd like technical support staff to reply: Please type the Captcha (no space) V. The problem is that once the bios got to 100% it was stuck there. 0 with virtual media over LAN and KVM-over-LAN support; ASPEED AST2400 with 10/100/1000M bps MAC; Network Controllers: Intel® Ethernet Controller I210-ATIntel® Ethernet Controller I217LMSupports 10Base-T, 100BASE-TX, and 1000BASE-T, RJ45 outputRealtek RTL8211E PHY (dedicated IPMI) Graphics: Aspeed AST2400 BMC Aug 11, 2016 · Problem is, my previous experience with X11SCA-F indicates it's not possible to have IPMI IKVM + active external display at the same time. As soon as you setup your IPMI on a Supermicro system, remember to change the default password right away. On Supermicro servers, IPMI can be configured either by using an open-source utility called IPMItool or by using BIOS through a VGA console or by using IPMICFG (Supermicro proprietary tool). impiEnabled and set value 0 or unchecked. Unplug it if you have no intention to use! On most Supermicro motherboards that won't help. Dec 30, 2020 · It’s important to know this! Supermicro has a default password of ADMIN. You need an unlock code from Supermicro to update the BIOS through IPMI. 9. . 980 Rock Ave. All three NIC´s (Dedicated IPMI, NIC 0 and 1) are connected to the network, but the Webinterface is unreachable. 4. 8th/9th Generation Intel® Core™ i3/Pentium®/Celeron® Processor, Intel® Xeon® E-2100 Processor, Intel® Xeon® E-2200 Processor. You may set it to dedicated if you want IPMI connection stays at dedicated port. IPMICFG 产品特点:. 0-U6. 0 Management. For IPMI initialization, no matter you shift the JPB1 jumper to enable or disable BMC, BIOS still do IPMI initialization and the time required to boot is almost the same. #7. S. Supermicro 16GB SATA DOM. 其命令行工具提供了标准 IPMI 指令与 Supermicro 专属的 OEM 指令用于作BMC/FRU 配置。. Set "UTC Timezone" to the current offset (GMT-07:00 for PDT). We now feed OpenSSL the configuration and private key files and instruct it to output a new CSR. For the Supermicro Server Manager question, it requires IPMI IP and activated SPT-OOB-LIC on each IPMI for the SSM to detect the system. Was this FAQ helpful? YES NO. Windows 7 + IE7 + Java7 at home connected by LAN in a ROUTER WITH STATIC IP. here. Please go to IE >> Internet Option >> Advanced >> uncheck “Use TLS 1. 此命令列介面工具可在 UEFI、DOS、Windows 与 Linux 操作系统上执行,毋需安装。. "Failover" allows for both dynamic and manual switch from dedicated port connection to LAN 1 when dedicated IPMI connection fails. BU Server: TrueNAS-13. Let the capacitors bleed. 1+. key -new -config node1ipmi. For step 6 look for VMkernel. Description. It will only work on the port closest to the IPMI dedicated port. See the Notes section of this article for more information on failover, shared or dedicated configurations. Jan 26, 2016 · Jan 26, 2016. Mar 21, 2024 · Access the IPMI interface using a web browser and the IP address specified in Network > IPMI. For X12DDW, you will need AIOM NIC IPMICFG 是一款用來配置 IPMI 裝置的本機端 (In-band/Local) 工具。. Changing NIC failover mode. #3. How to reconfigure IPMI using ipmitool? This article provides the steps to change the IPMI network settings on Nutanix nodes using the command-line tool ipmitool. Jan 1, 2011 · Here's what you need to do: take the LAN cable connected to the IPMI port. exe -dhcp off. Sep 14, 2015 · Tag the IPMI VLAN on your switchport and input the VLAN ID into the Supermicro network settings page. 0-U5. Release Notes. May 5, 2017 · If you want to setup IPMI to work over the non-dedicated LAN port, leave it in Failover and assign a static IP. com. This OEM command will enable or disable all non-IPMI services on the BMC. 0. com for more information. You can do this by connecting to IPMI using a web browser. ipmitool lan set 1 access off. This command can be used to enable or disable non-IPMI services such as ssh, http, https, and vnc. 1. Changing fan speeds for X9/X10 series boards. Thus the BIOS can be updated from IPMI only if the license key is available. 32GB 2x Crucial ECC DDR3 1600 CT2KIT102472BD160B. Mar 25, 2018 · 15. May 15, 2016 · Until today I tought it would be safe to simply unplug the IPMI cable. 10,080. Show : 13. Solution: switch the machine off, including PSU. 設定 IPMI IP 位址 Jul 24, 2020 · In the IPMI web interface, you can disable the in-band interface to preclude any possibility of interference with the main LAN interface. Our IPMI firmware only supports TLS 1. Hopefully this helps get your server set to the properties and security for your specifications. 1 Features If you put Rule 1 as 0. IPMICFG 是一款用来配置 IPMI 装置的本机端 (In-band/Local) 工具。. It is designed for easy to use and no pre-installation required. Follow the section Setting advanced configuration options using the vSphere Client for ESX/ESXi 3. 11 –U ADMIN –P ADMIN raw 0x30 0x70 0x0C 1 0 // for ATEN LAN mode get: Input : NetFn 0x30 Cmd 0x70 Param1 0x0c Param2 0 [read] Output: Completion Code 0x00 Data [dedicated/onBoard/failover] LAN mode set: Input : NetFn 0x30 Cmd 0x70 Param1 4. Extract the archive and copy the contents of the 'DOS' folder on to your bootable DOS USB. 1, Supermicro X10SRH-cF with E5 1650-v4 CPU, 96 GB ECC RAM, 8x 4TB WD Red in RAIDZ2 + 8x 4TB WD Red in RAIDZ2 as local backup pool in Norco RPC-4224 chassis. ASUS WS C621E SAGE ASMB9 IKVM Login. IPMICFG. The link I posted tells you how to unlock the remote BIOS Update License. should the software and/or materials prove defective, you (and not super micro computer inc. To disable/silence alarm from MegaRAID Storage Management: Select the controller affected by the Supermicro | Server Storage, Innovation, Cloud and AI To be able to change network settings of IPMI, this parameter should be set to disable to the time of change. For information on Backpanel USB and Front Panel USB ports, refer to page 2-21. Here you can change the default administrative user name and Yes. During the bootup process, my screen tells me the IP address and you need to ensure you are using that one. Be sure to use the correct cable for each header or connector. 2. CPU. xx. Enter your email address below if you'd like technical support staff to reply: Please type the Captcha (no space) X. If i changed the "Lan Interface" from default "Failover" to "Share" or "Dedicate" the IPMI Webinterface is unreachable. 0” and check “use TLS 1. authorized representative shall create a warranty or in any way increase the scope of this warranty. It will prompt for a license key to activate components from the IPMI interface. The popups are caused by Supermicro being dumb. You can disable it in the BIOS. These addressed issues for Java and moved many iKVM's over to HTML5. P. Since most of the Supermicro motherboards that support IPMI have on-board NICs, so the 1st NIC becomes the IPMI failover. Then we click on BIOS Upload from the Aug 16, 2015 · Set IP. Enter Comments Aug 6, 2021 · Aug 6, 2021. 1c). Make the IPMI VLAN a native VLAN on the switchport, and disable VLAN tagging for IPMI on your Supermicro. As a result, IT administrators can take advantage of these two security features while provisioning or maintaining a system. The Supermicro BMC sometimes tries to autodetect the IPMI port, and sometimes makes the wrong decision. Dec 16, 2023 · Select the controller affected by the issue. #2. ipmitool lan set 1 access on. 38cm) Processor. BIOS Configuration. IPMI Securityは進化した トピックであり、Supermicroは、自社製品のセキュリティーの向上やタイム リーなファイームウェア提供を行うため、積極的かつ継続的にITセキュリティー コミュニティーや顧客と取組んできました。. I've set a static IP. This is the result of my experiment of X11SCA-F + viewsonic monitor 2407h which has both hdmi and vga output, the cpu is i5-8400t. (This is the tricky part) Unplug power from the machine. I would like to know if I can somehow tell the BMC to not sound an audible alarm when the chassis cover is off because I frequently need to have it off. Enter your email address below if you'd like technical support staff to reply: Please type the Captcha (no space) 6. To adjust your fan speed profile, you can use either Supermicro's IPMICFG, or set it from the IPMI web interface. IPMI service is affected by an authentication bypass. Command confirmed to work on Supermicro X8DTG. It is Dedicated and Shared (on LAN1). You will typically be given three to five fan speed modes to choose from. Use safari or internet explorer. The Java issue is largely taken care of now with any IPMI firmware 2. exe req -out node1ipmi. Chrome works 100% fine. Tip: If you’re using an older Supermicro motherboard such as the X8, it’s auto detection can cause issues where IPMI stops responding. Download ZIP 1. Aug 21, 2019 · I bought a Supermicro X10SLM-F off ebay and it had a very old firmware and bios. Go to Configuration > Network, and scroll down to the drop-down list for LAN Interface, or Default Interfaces. 2. IPMI has a failover option - it'll switch IPMI interface to one of the standard ethernet ports, and often in my experience fail to establish any connection if there's anything else using that port. Oct 27, 2015 · LAN Interface: This feature allows the user to select the port to be used for IPMI out-of-band communication. It's always a good idea to upgrade IPMI firmware, for security reasons, add functionalities as IPKVM/Html5; as long as I know, you can downgrade it to an earlier version in the same "major" revision, meaning if your firmware version is 3. Supermicro X10SL7-F. Event Log can clear all or individual events. 50. May 29, 2018. If you're not seeing the IPMI, that may be bad. Some of these services include VNC for debugging an OS, access to http/https ports for locally configuring BMC settings and reading server health, and Here’s the link for the IPMI manual explaining setup and features. Supermicro IPMICFG User’s Guide 1. Jun 17, 2006 · The failover option makes the nic act like a three port switch with IPMI, normal i210 nic and the connection to the rest of your network. by super micro computer inc. IPMI version 2. Note: Your comments/feedback should be limited to this FAQ only. You need a router to access it from another Lan. T. cfg. F. Disable DHCP. Enter your email address below if you'd like technical support staff to reply: Please type the Captcha (no space) N. Thank you for the info! I will have to fire up IPMI, as I haven't played with it (recent servers are Dell). Select “Disable”, “Enable”, or “Silence” from the drop-down menu and click “Submit”. Mar 8, 2018 · Mar 8, 2018. May 31, 2015 · 5. V. In the System BIOS the "ipmi network link status" is "no connect" and the "ipmi lan selection" shows "share lan". IPMICFG 產品特點:. Jun 5, 2018 · Main System: TrueNAS-13. The next step is to submit the CSR to your certificate authority (CA) – of course the instructions here The BIOS and the IPMI are totally separate, except that the IPMI can write to the BIOS in order to update it. However, it will silently fallback to LAN1 if there's no cable plugged into the IPMI connector! The quick reference guide that came with the board lists jumper JPB1, which "enables or disables BMC" (IPMI). 1. 6x8TB Shucked WD Easystore RAIDZ2. Enter your email address below if you'd like technical support staff to reply: Please type the Captcha (no space) Jan 10, 2017 · 1. The Standard Speed profile is temperature controlled, with a base fan speed at 50% PWM duty cycle. C. Macbook + Chrome + Java7 at home connected by wifi to a ROUTER WITH STATIC IP. Supermicroは、定期的なファームウェア Or you can use IPMICFG by doing the following: Run ipmicfg as administrator, to check the current lan mode: ipmicfg -raw 0x30 0x70 0x0c 00 it will return value: 00 = dedicated, 01 = share, 02 = failover to change lan mode: ipmicfg -raw 0x30 0x70 0x0c 01 0# (in place of the # you can use 0 = dedicated, 1 = share, 2 = failover) You may also use the shared IPMI/1G port in place of the dedicated port, as long as the BMC is configured to use it, but it is less reliable than the dedicated port. Sensor reading color will be green if between non critical, yellow for critical and red for non recoverable. Click “Next” until locating the “Alarm Control” entry. or a super micro computer inc. By default it is set to Failover, meaning if it does not detect connection on Dedicated, it will look for connection on Shared and IPMI will run on that port. # ipmiutil smcoem lanport failover Connecting to the IPMI interface. Share. Doing some research, I found this Mar 15, 2012 · Make sure it is what you expect it to be. Use it for basic IPMI configuration and BMC status reading and monitoring. Jan 26, 2016 · Don't use chrome it has Java disabled partially. May 7, 2015 · IPMI plugin for unRAID 6. chrisolson09 said: In my research it says that when you run IPMI over a LAN port that it has to be the LAN1 port, the problem comes in for me though is that this board does not have the LAN1/2 ports based on the schematicit only has the 3/4 LAN ports and I'm wondering if this is the reason why it's not working. Enter Comments Below: Note: Your comments/feedback should be limited to this FAQ only. 6. x in KB1038578 to disable. SMCIPMITool Key Features: Remote IPMI Management. 1 build, running since 9. Reset to the factory default. SFT-OOB-LIC. Model. While the IPMI standard protocol defines UDP port 623 for RMCP communications, there are additional remote services that BMCs provide to efficiently provision and debug servers. However a simple explanation is that our boards has two ports for IPMI. There's an argument tag set in the jnlp file that's left blank. Enter your email address below if you'd like technical support staff to reply: Please type the Captcha (no space) IPMI 2. I rebooted and am caught in an infinite reboot loop, it never makes it to even the BIOS options, nor letting me boot from USB. ledude1. Reset IPMI unit to default factory setting to reverse the above process. From the FAQ you yourself posted: Or if you have the OOB remote Bios update license, shut down the system and update the Bios using the IPMI remote interface. miguellee said: The IPMI if function ok on the dedicated lan port. For X12DPU, the NICs on the Ultra raiser are on-board NICs. IPMI connection could go through LAN 1 when dedicated port connection gets lost in failover mode. If your default username and password is something like “admin / admin”, “root / password”, “root / calvin” for Dell EMC, “ADMIN / ADMIN” for Supermicro, or similar, it is exceedingly easy for a malicious user to try default logins. 19 and above. Note. Dec 3, 2019 · Update Supermicro BIOS using IPMI. Example of CLI : Ipmitool –H 172. 6" (24. You don't mention if you are using the dedicated IPMI port or using the IPMI port in shared mode on the primary interface. Wait for IPMI to go out. Xeon E-3 1240V3. Up to 6 cores, 12 threads. Nutanix Support & Insights Loading Sep 7, 2017 · SMCIPMITool is an out-of-band Supermicro utility that allows a user to interface with SuperBlade systems and IPMI devices via CLI (Command Line Interface). IPMI is required (since it monitors the sensor), and SSM aggregates all the IPMI’s in your datacenter and provides Note: Your comments/feedback should be limited to this FAQ only. http ://<<ip address>) to use the SuperMicro IPMI web UI. 1 Recommend. C:\OpenSSL\bin>openssl. Log in to the management interface. To configure the network settings for the IPMI module in the BIOS, you must first start the server and enter the BIOS. Alternatively, you can press the DEL key during POST to enter the BIOS and then navigate to IPMI > BMC Network Configuration. exe –fd. ipmicfg -sdr del sensor_number to disable the alert. Go to Configuration -> Network and then change Lan Interface: to "Dedicated". The Supermicro X13/H13/X12/H12 platform's BMC (Baseboard Management Controller) is built on the ASPEED AST 2600. g. The default setting is Failover, which will allow IPMI to be connected from either the shared LAN port (LAN1/0) or the dedicated IPMI LAN port. Watchdog is enabled in BIOS settings. "Share" is using LAN1 as primary IPMI connection. admin. Here is how to do that correctly: syscfg /lfo disable. 2” >> then push Apply and OK button >> to fix this issue on IE 10. This includes a KVM Console function. Was this FAQ helpful? In general, you will need NIC with NCSI interface and SI cable to connect the NIC to the NCSI header on the motherboard to BMC. The only thing actually using Java is the KVM client, which is downloaded as a JNLP file anyway. mynet, and try to start up the java KVM then the jnlp file created by IPMI doesn't get the server IP address properly populated. 10 not 2. IPMICFG は、IPMI デバイスを構成するためのインバンドユーティリティで、標準の IPMI と Supermicro® 独自の BMC/FRU 向け OEM コマンドを提供するコマンドラインツールです。. Motherboard Type: BIOS for older products. This plugin is for viewing the local or remote sensors and event logs of a motherboard with ipmi. 具备基板控制器 (BMC Supermicro | Server Storage, Innovation, Cloud and AI We would like to show you a description here but the site won’t allow us. After that, you can un-plug the network cable at Dedicate LAN Port. 1, Supermicro X10SL7-F with G3258 CPU, 16 GB ECC RAM, 8x 4TB WD Red in RAIDZ2 (encrypted) in Fractal-Design Node 804 case. FAQ ID. Make sure you've got your network plugged into the IPMI port. IPMI does not work on LAN2. Java web start IKVM failure: If I access IPMI through a DNS name, for example: ipmi. authorized representative) assume the entire cost BMC/IPMI Virtual Media is a feature of the Virtual Console that enables users to attach a CD/DVD image to the server as a virtual CD/DVD drive. It is a command line tool providing IPMI commands and Supermicro proprietary OEM commands. Linux Virtual Machine + Firefox inside MacBook at home connected by wifi to a ROUTER WITH STATIC IP. The Aug 21, 2019 · I bought a Supermicro X10SLM-F off ebay and it had a very old firmware and bios. jgreco said: The system will boot if it is set up to, and if it can. Check "Automatically synchronize Date & Time with NTP Server". San Jose, CA 95131 U. IPMI plays very little part in the boot process under normal circumstances. You will also find links to other resources and guides on IPMI configuration and troubleshooting. Helpdesk@bytesizedalex. Jan 18, 2017 · emailAddress = IT. In this case watchdog works as expected -- system was stable for 25 minutes with bmc-watchdog running and rebooted after watchdog program termination. Set NTP Server to the name of the NTP server. Messages. To set up the NTP: 1. or super micro computer inc. #1. x, and 5. Answer: In basic terms, "dedicate" mode is using the dedicated IPMI port connection. Supermicro BMC solution can configure BIOS secure features, Secure Boot, and Secure Drive Erase via Redfish's secure interface. x also enabled redfish support and credential verification via secure LDAP. Eventually, I found a little bit strange solution: just leave watchdog jumper (JWD1) open (with neither NMI nor hard-reset selected). Use the following guideline when connecting the IPMI port on G4 and later platforms: if you use the shared IPMI port, make sure that the connected switch can auto-negotiate to 100 BIOS & BMC & Bundled & Microcode Package Download. supermicro. Nov 16, 2009 · If you have physical access to the server, follow these simple steps to reset the ADMIN password on your IPMI: Create a bootable DOS USB stick using Rufus. A. 0 Password Hash Disclosure – that is CVE-2013-4786, our document showed it is fixed in X9 firmware 3. 31. Please email to support@supermicro. Precedence is given to the Dedicated LAN port over the shared LAN port. I've actually had to do the following to get IPMI working: Configure IPMI to use either dedicated IPMI or sideband IPMI. The default setting is Fail Over, which chooses to use either the dedicated IPMI port or the first set-bmc-services-status enable|disable. Identified by researchers in the lab, the vulnerabilities have When IPMI Lan Selection set in "Failover" mode then which AIOM-LAN is activated for IPMI failover? Answer The LAN port of JAIOM1, which is on the left hand side of the MB, is activated for this Failover IPMI LAN Selection. To do this, re-boot the server and press Del (for Supermicro motherboards) during the Power-On Self-Test (POST). com Europe Address: Super Micro Computer B. 38cm x 24. Feb 9, 2022 · BMC IP address appears in the bottom right during POST. Service ports. The failover works like this: if there is a link up on dedicated port, the system at start will used that. Two kinds of user modes are provided when you start the SMCIMPITool: Command Line Mode and Shell Mode. In IPMI Web UI, select "Date & Time" from the Configuration menu. 168. Enter your email address below if you'd like technical support staff to reply: Please type the Captcha (no space) 9. May 29, 2018 · May 2, 2015. Show entries. To recover from this, you need to reset it to factory defaults locally. com (General Information) support@supermicro. TrueNAS 13. Reboot IPMI unit to make setting effective. This is an expected behavior as the BIOS code can’t auto bypass BMC step by detecting jumper status. csr -key node1ipmi. 6" x 9. If there is nothing plugged into the IPMI they just 'share' the normal LAN port to expose IPMI to the network. The IPMI/BMC audible alarm is sounding sporadically on the motherboard. 0/0 and Block, then you put your IP as Rule 2 and Allow. 30 you can downgrade it to 3. Enter your email address below if you'd like a technical support staff to reply: FAQ Stats. Refer to your IPMI device documentation to learn the default administrator account credentials. Secure boot is part of the UEFI firmware standard (since 2. 0 is not supported. Workaround #1: If you edit the downloaded jnlp file and add For IPMI v2. com (Technical Support) Web Site: www. IPMICFG Overview IPMICFG is a utility for IPMI devices configuration. For technical support, please send an email to support@supermicro. To update the BIOS from the management panel. xd ka va ib hc mq vr pz pm zb